Configure a USB Barcode Scanner

Before using a USB barcode scanner with CompuTec WMS, you must configure it with the required settings. The following sections provide model-specific configuration instructions.

Configure Honeywell MS5145 LS USB Scanner​

To work correctly with CompuTec WMS, the Honeywell MS5145 LS USB scanner must be configured to send:

  • Prefix: 002
  • Suffix: 003

Follow the steps below to configure the USB scanner.

Before you start​

Make sure you have access to the configuration barcodes for the Honeywell MS5145 LS USB scanner.

Configure the USB scanner​

To configure the USB scanner, follow these steps:

  1. Scan the Enable Factory Defaults barcode.

    alt text

  2. Scan the Recall Defaults barcode.

    alt text

  3. Scan the Enter/Exit Programming barcode to enter the programming mode.

    alt text

  4. Scan the Configurable Prefix #1 barcode.

    alt text

  5. Next, scan the following digits in order: 0 0 2.

    alt text alt text alt text

    This configures the scanner to send the prefix 002.

  6. Scan the Configurable Suffix #1 barcode.

    alt text

  7. Next, scan the following digits in order: 0 0 3.

    alt text alt text alt text

    This configures the scanner to send the suffix 003.

  8. Scan the Enter/Exit Programming barcode again to exit programming mode and save the configuration.

    alt text

Result​

The USB barcode scanner is now configured to send:

  • Prefix: 002
  • Suffix: 003