This guide provides step-by-step instructions on configuring Precisa weighing devices for seamless integration with CompuTec PDC. It covers tested devices, device settings, and necessary configurations within CompuTec Gateway Manager.

Tested Devices​

The following Precisa models have been tested and confirmed to work with CompuTec PDC:

  • Precisa XB320M
  • Precisa BK1200D
  • Precisa XB120A

Device Configuration​

To ensure proper communication between the scale and CompuTec PDC, adjust the following settings on the device:

  • Date and Time ON
  • Balance-ID ON
  • Product-ID ON
  • Gross and Tare ON
  • Units ON
  • Operator-ID OFF
  • Line Feed OFF

Set Interface​

  • BaudRate 9600
  • Parity 8-NO-1Stop
  • Handshake NO
  • PC Direct Mode OFF

Set Date And Time​

  • Date [DD.MM.YY]

Configuration in CompuTec Gateway Manager​

To integrate the Precisa scale with CompuTec PDC, configure the following parameters in CompuTec Gateway Manager:

  • Scale name: for example, “Precisa XB320M”
  • Localization: for example “MG11”
  • Barcode: for example “123456”
  • Tolerance: format NUMBER[UoM] for example 0.001g
  • Range From: format NUMBER[UoM] for example 0.2g
  • Range To: format NUMBER[UoM] for example 300g
  • Session Life Time (s): left default 900
  • Port: the same as the device
  • Parity: the same as the device
  • BaudRate: the same as the device
  • Handshake: the same as the device
  • Data bits: the same as the device
  • Stop bits: the same as the device

Regular Expression​

Date\s*(?<DATE>[0-9]{1,2}.[0-9]{1,2}.[0-9]{4})\s*Time\s*(?<TIME>[0-9]{1,2}:[0-9]{1,2}:[0-9]{1,2}).*Serialno\s*:\s*(?<SerialNO>\d*).*N\s*:\s*[a-zA-Z]*\s*(?<minus>[-+]*)\s*[a-zA-Z]*\s*(?<NetWeight>[0-9.]*)\s*(?<Uom>(?![GT])[a-zA-Z]{1,2}).*G\s*:\s*[a-zA-Z]*\s*[-+]*\s*[a-zA-Z]*\s*(?<GrossWeight>[0-9.]*).*T\s*:\s*[a-zA-Z]*\s*[-+]*\s*[a-zA-Z]*\s*(?<Tare>[0-9.]*)